Promise Technology J310s J610s Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Disková pole Promise Technology J310s J610s. Promise Technology J310s J610s User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Version 1.0

VTRAKJ610S, J310SPRODUCT MANUALVersion 1.0

Strany 2 - Trademarks

VTrak J610s, J310s Product Manual6SpecificationsDrive Capacity: J610s, 16 drives. J310s, 12 drives.External I/O Ports: SAS host port and SAS expansion

Strany 3 - Contents

Chapter 1: Introduction7Dimensions (H x W x D): J610s, 13.1 x 44.7 x 56.1 cm (5.2 x 17.6 x 22.1 in)J310s, 8.8 x 44.7 x 56.1 cm (3.5 x 17.6 x 22.1 in)N

Strany 4

VTrak J610s, J310s Product Manual8

Strany 5 - Chapter 1: Introduction

9Chapter 2: Installation• Unpacking the VTrak (below)• Mounting VTrak J610s in a Rack (page 11)• Mounting VTrak J310s in a Rack (page 13)• Installing

Strany 6 - Overview

VTrak J610s, J310s Product Manual10 Figure 1. VTrak J610s rear view Figure 2. VTrak J310s rear view Some J610s and J310s units ship with a single I/O

Strany 7

Chapter 2: Installation11Mounting VTrak J610s in a RackThe J610s subsystem installs to the rack using the supplied mounting rails. You can also use yo

Strany 8 - Architectural Description

VTrak J610s, J310s Product Manual124. Square the rail assemblies in the rack.5. Tighten the adjustment screws and the attaching screws.6. Place the VT

Strany 9 - Features and Benefits

Chapter 2: Installation13Mounting VTrak J310s in a RackThe J310s subsytem installs to the rack using the supplied mounting rails. You can also use you

Strany 10 - Specifications

VTrak J610s, J310s Product Manual14The rail is designed to slide freely over the plate.5. Attach a flange to each end of the rail, with the rail on th

Strany 11 - MIC Statement

Chapter 2: Installation15 Figure 7. Mounting rail installationInside of postRack front postRail attaching screw(not included)Rail adjustment screwMoun

Strany 12

VTrak J610s, J310s Product ManualiiCopyright© 2007 Promise Technology, Inc. All Rights Reserved.Copyright by Promise Technology, Inc. (Promise Technol

Strany 13 - Chapter 2: Installation

VTrak J610s, J310s Product Manual16Installing Disk Drives Populate the VTrak with 3.5-inch SAS or SATA disk drives.Install all of the drive carriers i

Strany 14

Chapter 2: Installation17If you installed an AAMUX, lay the SATA disk drive in the carrier and slide it so the power and data connectors insert in to

Strany 15

VTrak J610s, J310s Product Manual18 Figure 10.Drive carrier with SATA disk drive and AAMUX Cautions• If you plan to operate your VTrak with fewer t

Strany 16

Chapter 2: Installation19Drive NumberingEach disk drive in the J610s and J310s units is identified by a number that corresponds to the Port number use

Strany 17

VTrak J610s, J310s Product Manual20Setting Up Data Cable ConnectionsThe VTrak J610s or J310s unit provides Direct Attached Storage (DAS) support to th

Strany 18

Chapter 2: Installation21 Figure 15.VTrak J610s and J310s I/O modules have one subtractive-routed port and one table-routed portEach I/O module has on

Strany 19

VTrak J610s, J310s Product Manual22Basic DAS Connection Figure 16. An example of a basic DAS connection between one Host PC and one VTrak J310s unit.

Strany 20 - Installing Disk Drives

Chapter 2: Installation23Cascading DAS ConnectionIf you are using multiple J610s or J310s units and want to manage them from the same SAS HBA card, co

Strany 21

VTrak J610s, J310s Product Manual24Redundant DAS ConnectionThe arrangement below is a DAS system with full redundancy. Figure 18. An example of a redu

Strany 22

Chapter 2: Installation25The arrangement requires J610s or J310s units with dual I/O modules and two Host PCs with a SAS HBA card in each PC.Connect t

Strany 23 - Drive Numbering

iiiContentsChapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1About This Manual . . . . . . . . . . .

Strany 24

VTrak J610s, J310s Product Manual26If your PC has two DB9 COM ports, and your J610s or J310s unit has two I/O modules, you can connect a second null-m

Strany 25

Chapter 2: Installation27 Figure 21.VTrak J610s/J310s disk carrier LEDsWithin one minute, the Power/Activity should display Green. If there is no disk

Strany 26 - Basic DAS Connection

VTrak J610s, J310s Product Manual28

Strany 27 - Cascading DAS Connection

29Chapter 3: Management• Front Status Indicators (below)• Drive Status Indicators (page 24)• I/O Module Status Indicators (page 25)• CLI Command Set (

Strany 28 - Redundant DAS Connection

VTrak J610s, J310s Product Manual30 Drive Status IndicatorsAfter a few moments the Power/Activity should display Green. If there is no disk drive in t

Strany 29

Chapter 3: Management31I/O Module Status IndicatorsThe VTrak J610s or J310s I/O module has LEDs that indicate activity on each of its ports.Figure 3.

Strany 30 - Connecting the Power

VTrak J610s, J310s Product Manual32Figure 4. VTrak J610s power supply and fan LEDsThe battery LED on the cooling unit has no function on the VTrak J61

Strany 31 - Setting Up the CLI Connection

Chapter 3: Management33CLI Command SetThe CLI has the following set of commands:cable – Specifies the length of cable for optimal signal quality.enclo

Strany 32

VTrak J610s, J310s Product Manual34cli>cableCN#1 Cable Length = 1 meterCN#2 Cable Length = 3 meterNote the cable length change for CN2.Enclosure Co

Strany 33 - Chapter 3: Management

Chapter 3: Management35I/O Module ID: 1 Max Num Of I/O Modules: 2FwVersion: 1.00.0000.00 I/O Module Role: PrimaryMaxNumOfHDSlots: 12 MaxNumOfPSUs: 2Ma

Strany 34 - Drive Status Indicators

VTrak J610s, J310s Product ManualivChapter 4: Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43Frequently Aske

Strany 35 - I/O Module Status Indicators

VTrak J610s, J310s Product Manual36D01 SAS Addr: 50 00 15 E0 11 4E 5E B2D02 SAS Addr: 50 00 15 E0 11 4E 80 C2D03 SAS Addr: 50 00 15 E0 11 4C 22 02D04

Strany 36

Chapter 3: Management37For this command, a 1 enables and a 0 disables.To set the minimum fan speed to medium high, at the cli> prompt, type enclosu

Strany 37 - CLI Command Set

VTrak J610s, J310s Product Manual38P13 CN1 SAS 3.0G OK End ---- RdyP14 CN1 SAS 3.0G OK End ---- RdyP15 CN1 SAS 3.0G OK End ---- RdyP16 CN2 ---- ---- -

Strany 38 - Enclosure Command

Chapter 3: Management39P15 ---------- ---------- ---------- ---------- ---------- ---------- 0x01P16 ---------- ---------- ---------- ---------- -----

Strany 39

VTrak J610s, J310s Product Manual400488 500000E01122C0F3 0x10 CN1 ---- 00519 500000E01122C493 0x10 CN1 ---- 00731 500000E01122C5B3 0x10 CN1 ---- 00751

Strany 40 - Settings

Chapter 3: Management41VPDR CommandThe vpdr command displays vital product data on the major components of the J610s or J310s unit. There are six comp

Strany 41 - Link Command

VTrak J610s, J310s Product Manual42

Strany 42

43Chapter 4: Support• Frequently Asked Questions (below)• Contacting Technical Support (page 44)• Limited Warranty (page 47)• Returning product for re

Strany 43 - Route Command

VTrak J610s, J310s Product Manual44In addition, leaving one power supply off reduces air flow through the J610s or J310s enclosure and can contribute

Strany 44 - Uptime Command

Chapter 4: Support45United StatesThe Netherlands GermanyItalyE-mail Support e-Support On-LineFax Support (408) 228-1097 Attn: Technical SupportPhone

Strany 45 - ? Command

1Chapter 1: Introduction• About This Manual (below)• Overview (page 2)• Architectural Description (page 4)• Features and Benefits (page 5)• Specificat

Strany 46

VTrak J610s, J310s Product Manual46Taiwan China E-mail Support e-Support On-LineFax Support +886 3 578 2390 Attn: Technical SupportPhone Support +886

Strany 47 - Chapter 4: Support

Chapter 4: Support47Limited WarrantyPromise Technology, Inc. (“Promise”) warrants that for three (3) years from the time of the delivery of the produc

Strany 48 - Contacting Technical Support

VTrak J610s, J310s Product Manual48No other document, statement or representation may be relied on to vary the terms of this limited warranty.Promise’

Strany 49 - The Netherlands

Chapter 4: Support49The technician will assist you in determining whether the product requires repair. If the product needs repair, the Technical Supp

Strany 50 - Attn: Technical Support

VTrak J610s, J310s Product Manual50

Strany 51 - Limited Warranty

51Appendix A: Second I/O ModuleThe VTrak J610s and J310s units ship with one or two I/O modules. If your J610s or J310s came with only one I/O module,

Strany 52 - Returning Product For Repair

VTrak J610s, J310s Product Manual52

Strany 53

53IndexSymbols? command 41AAAMUX adapter 16, 18, 30About This Manual 1Attached SAS addresses 34automatic shutdown setting 36Bblower status 34Ccablecom

Strany 54

VTrak J610s, J310s Product Manual54II/O module 10, 26add second module 51default primary 20dual 25role 34, 43, 51SAS ports 22, 23LLEDscooling unit 32d

Strany 55 - Appendix A: Second I/O Module

Index55Serial cable connections 25, 27settingautomatic shutdown 36minimum fan speed 36temperature 36thermal management 36Specifications 6Status Indica

Strany 56

VTrak J610s, J310s Product Manual2OverviewThe Promise VTrak J610s and J310s are optimized for organizations deploying cost-effective small-to-medium a

Strany 57

VTrak J610s, J310s Product Manual56

Strany 58

Chapter 1: Introduction3Figure 3. VTrak J610s rear view Figure 4. VTrak J310s rear viewThe two external SAS ports provide the needed connectivity and

Strany 59

VTrak J610s, J310s Product Manual4Architectural DescriptionThe VTrak J610s packs up to 16 drives per system, offering industry-leading capacity in jus

Strany 60

Chapter 1: Introduction5Features and Benefits Feature Benefit3U or 2U 19-inch wide enclosure Installs easily in any standard rackmount.Supports Seria

Komentáře k této Příručce