VessRAID 1000i Series Product Manual
268
RAID 10
A RAID 10 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 10 must have less than 16 physical drives.
RAID 6 4 physical drives minimum, 16 maximum.
RAID 10 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Add physical drives.
Even number of physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Zobrazit stránku 283