Promise Technology VTrak J610S Manuál Strana 403

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 440
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 402
Appendix B: Multipathing on Windows
385
4. Click the Apply button.
5. Click the OK button in the confirmation box.
The new setting takes effect immediately.
See also:
“Load Balance Policy” on page 383.
“PDO Removal” on page 385.
“Refreshing the Objects” on page 387.
PDO Removal
PDO removal refers to the action of deleting a multipath input/output (MPIO) disk
from the Windows Device Manager after all paths to a physical device object
(PDO) have failed.
PDO removal interval refers to the period of time in seconds between the
moment all paths to a PDO are disconnected and the MPIO disk disappears from
the Device Manager.
Changing PDO Removal Settings
To change PDO removal settings:
1. Do one of the following actions:
Click the Advanced Settings icon.
From the Operations menu, choose Advanced Settings.
The Advanced Settings dialog box appears with the MPIO Parameters tab
displayed.
2. Click the arrows or type a new value in the PDO Remove Period field to
change the interval.
120 seconds is the Promise-recommended default value.
3. Click the Apply button.
4. Click the OK button in the confirmation box.
The new setting takes effect immediately.
See also “Path Verification” on page 384.