Promise Technology Network Device EX8650 Uživatelský manuál Strana 244

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 318
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 243
SuperTrak EX Series User Manual
230
RAID 60 Axles
When you create a RAID 60, you must specify the number of axles. An axle
refers to a single RAID 6 logical drive that is striped with other RAID 6 logical
drives to make RAID 60. An axle can have from 4 to 16 physical drives,
depending on the number of physical drives in the logical drive.
The chart below shows RAID 60 logical drives with 8 to 20 physical drives, the
available number of axles, and the resulting distribution of physical drives on
each axle.
RAID 60 Logical Drive
No. of Drives No. of Axles Drives per Axle
824,4
924,5
10 2 5,5
11 2 5,6
12 2 6,6
34,4,4
13 2 6,7
34,4,5
14 2 7,7
34,5,5
15 2 7,8
35,5,5
16 2 8,8
35,5,6
4 4,4,4,4
17 2 8,9
35,6,6
4 4,4,4,5
Zobrazit stránku 243
1 2 ... 239 240 241 242 243 244 245 246 247 248 249 ... 317 318

Komentáře k této Příručce

Žádné komentáře