Chapter 5: SmartNAVI
205
When the controller shuts down, your SmartNAVI connection is lost.
4. Wait for no less than two minutes.
5. Manually turn off the power supply switch (both switches with redundant
power supplies) on the back of the subsystem.
Monitoring the Shutdown
To monitor a shutdown, you must use the Command Line Interface (CLI) though
a serial connection to the VessRAID.
Turn off both power supply switches when the following this message appears:
Shutdown complete. It is now safe to power off the subsystem.
Caution
After you power off the subsystem, wait at least 10 seconds before
you power on the subsystem again.