VTrak M-Class Product Manual
96
4. Click on the Channel 1 or the Channel 2 link.
The settings screen displays a list of the 16 Targets and Termination for the
selected SCSI channel.
To enable a SCSI target:
1. Check (click on) the TID box beside the target you want to enable.
Checked means enabled, unchecked means disabled.
2. Click the Submit button.
To set Termination for the VTrak SCSI controller “Out” connectors:
1. From the Termination dropdown menu, select Automatic, ON or OFF.
Automatic means the termination function will set itself automatically.
2. Click the Submit button.
SCSI Target Information
1. Click the Subsystem icon in Tree View.
2. Click the Administrative Tools icon.
3. Click on the SCSI Management icon.
The Channel tab displays SCSI Channel Information:
4. Click on the Target tab.
The Target tab displays information about the 16 SCSI targets on each of the
two SCSI channels:
Status – Enabled or Disabled
Negotiated Transfer Rate – Data Transfer Rate in MB/s
Bus Width – Narrow or Wide
A value of N/A under Transfer Rate or Bus Width appears when the Target is
disabled. To enable a SCSI Target, see “SCSI Channel Settings” on page 95.
Note
You must restart the VTrak for new settings to become effective.
See “Shutdown and Restart” on page 109.
Cautions
Turn off termination only when the VTrak is NOT the last
device in the SCSI chain.
Internal termination only works on the “Out” SCSI connectors.