VTrak M-Class Product Manual
132
Disk Array Status
Functional/OK – This is the normal state of a logical drive. When a logical
drive is Functional, it is ready for immediate use. For RAID Levels other than
RAID 0 (Striping), the logical drive has full redundancy.
Synchronizing – This condition is temporary. Synchronizing is a maintenance
function that verifies the integrity of data and redundancy in the logical drive.
When a logical drive is Synchronizing, it will function and your data is
available. However, access will be slower due to the synchronizing
operation.
Critical/Degraded – This condition arises as the result of a physical drive
failure. A degraded logical drive will still function and your data is still
available. However, the logical drive has lost redundancy (fault tolerance).
You must determine the cause of the problem and correct it.
Rebuilding – This condition is temporary. When a physical drive has been
replaced, the logical drive automatically begins rebuilding in order to restore
redundancy (fault tolerance). When a logical drive is rebuilding, it will
function and your data is available. However, access will be slower due to
the rebuilding operation.
Transport Ready – After you perform a successful Prepare for Transport
operation, this condition means you can remove the physical drives of this
disk array and move them to another enclosure or different drive slots. After
you relocate the physical drives, the disk array status will show OK.
Forced Offline – This drive was forced offline by the user.
Forced Online – This drive was forced online by the user.
Transition Running – A Transition is running that involves this physical drive.
PDM Running – PDM is running on this physical drive.
Media Patrol Running – Media Patrol is running on this physical drive.
Stale – The physical drive contains obsolete disk array information. Click on
the Clear tab.
PFA – The physical drive has errors resulting in a prediction of failure. Click
on the Clear tab.
Offline – This condition arises as the result of a second physical drive failure.
An Offline logical drive is not accessible but some or all of your data may
remain intact. You must determine the cause of the problem and correct it.
Dead – The physical drive has failed.
Disk Array Settings
The Disk Array–Settings tab enables you to assign an alias to this disk array and
also enable or disable Media Patrol and PDM. To make Disk Array settings:
1. Click the Subsystem icon in Tree View.
Zobrazit stránku 139
1 2 ... 135 136 137 138 139 140 141 142 143 144 145 ... 315 316

Komentáře k této Příručce

Žádné komentáře